- Overview
- Product Parameters
- Product Description
- Packaging & Shipping
- Company Profile
Basic Info.
Product Description
*national defense engineering
*civil air defense engineering
*tobacco and petrochemical industries
*subway stations
*aerospace field
*purification engineering
*laboratories
*telecommunication equipment rooms
*archives
*food rooms
*pharmaceutical
*film workshops
*pecial glass manufacturing
*other places with dehumidification requirements
Air Cooled Temperature Regulating Type/ Air Cooled Cooling Type | ||||||||
Project Model | HCFW10 | HCFW15 | HCFW20 | HCFW25 | HCFW30 | |||
Dehumidifying Capacity | kg | 10 | 15 | 20 | 25 | 30 | ||
Refrigerating Capacity | KW | 17 | 25.5 | 34 | 42.5 | 51 | ||
Wind Circulation Capacity | m3/h | 3000 | 4500 | 6000 | 7350 | 8800 | ||
Power Supply | 3P/380V/50HZ Three Phases Five Wires System | |||||||
Power | kW | 6.05 | 10 | 11 | 15.2 | 16 | ||
Current | A | 14.1 | 23.4 | 25.7 | 35.5 | 37.4 | ||
Refrigerating Fluid | Type | R22 or R407C | ||||||
Safe Protection Unit | High and Low Pressure Protection,Current Overload Protection,Antifreezing Protection,Electronical Delayed Protection | |||||||
Indoor Unit | Fan | Type | Centrifugal Fan | |||||
Numbers | Unit | 1 | 2 | 2 | 2 | 2 | ||
Power | KW | 0.75 | 1.1 | 1.5 | 2.2 | 2.2 | ||
External Static Pressure | Front Wind Supply | Pa | 0 | |||||
Top Wind Supply | Pa | 50 | 50 | 80 | 80 | 100 | ||
Outline Dimension | L | mm | 880 | 1200 | 1400 | 1700 | 1700 | |
W | mm | 470 | 440 | 470 | 570 | 690 | ||
H(Front Wind Supply) | mm | 1870 | 1870 | 1940 | 2150 | 2150 | ||
H(Top Wind Supply) | mm | 1730 | 1750 | 1800 | 2000 | 2050 | ||
Weight | kg | 120 | 150 | 180 | 250 | 280 | ||
Outdoor Unit | Model | HAS1R-170 | HAS1R-250 | HAS1R-350 | HAS1R-450 | HAS1R-500 | ||
Compressor | Numbers | Unit | 1 | 2 | 1 | 2 | 2 | |
Power | kW | 4.3 | 7 | 8 | 11 | 13 | ||
Current | A | 7.0 | 12.0 | 14.0 | 17.5 | 20.0 | ||
Outline Dimension | L | mm | 720 | 815 | 845 | 1850 | 1850 | |
W | mm | 720 | 815 | 845 | 815 | 815 | ||
H | mm | 1060 | 1160 | 1160 | 1250 | 1250 | ||
Weight | kg | 150 | 215 | 280 | 460 | 460 | ||
Accessory Tube Size | Liquid Tube | in | 3/4″ | 3/4″×2 | 1-3/8″ | 7/8″×2 | 7/8″×2 | |
Gas Tube | in | 1/2″ | 1/2″×2 | 5/8″ | 5/8″×2 | 5/8″×2 |
Feature:
- Year-round ventilation
- Condenser is set inside exhaust, improving COP
- Condenser and evaporator are completely separated, prevent air cross infection
- Easy installation
- Used in ambient temperature -15 to 43 ºC
- Microcomputer control
Detailed Introduction:
The design and engineering of the condensing exhaust air heat recovery unit are more simplified: no complicated supporting equipment such as water piping is needed, which saves the equipment cost and makes the design simpler.
Ventilation throughout the year, regardless of the season and time period, it can comfortably and reasonably perform energy-saving operation under the set air conditions, and can also greatly save operating costs.
The condensing exhaust air heat recovery unit has high heat recovery efficiency: the condenser (evaporator) is designed in the exhaust channel to perform heat recovery on the exhaust air, which greatly improves the equipment cop value. Similarly, this design will not cause the equipment to overheat in summer and overcool in winter, which greatly improves the reliability of the equipment. There is no need to consider defrost and clean, low heating efficiency.
No cross pollution of air: Because the evaporator and condenser are completely separated from each other, there is no cross pollution caused by bacteria or odor, and it is very clean and clean.
Easy installation: The indoor and outdoor unit of the condensing exhaust air heat recovery unit is an integrated structure. No refrigerant pipe connection is needed, and only the air pipe is needed to run efficiently.
Strong environmental adaptability: The range of use is wide, the unit can operate efficiently in the environment of minus 15 degrees Celsius to 43 degrees Celsius, and the air supply and exhaust air balance design reduces the load of air conditioning. Recycling the cold or heat in the exhaust air, especially in winter, significantly improves the heating performance and achieves the effects of environmental protection, high efficiency and energy saving.
Precise control and multiple protection: The microcomputer control system can accurately monitor and adjust the operating status of the system, and automatically adjust the operation of the compressor according to the load change, with multiple protection functions