Ventilation, Heating and Dehumidification Air Handling Unit--Air Conditioning System

Introducing the efficient and reliable "AirMaster VHD-AC" air handling unit for ventilation, heating, and dehumidification. Perfect for factories.
Request a Quote

PRODUCTS DETAILS

Basic Info.

Model NO.
HAH
Mounting
Ceiling,Floor Standing
Lifetime
>20 years
Certification
ISO, CE, CCC
Condition
New
Coil Material
Blue Hydrophilic Aluminum Fin/Copper
Delivery Time
25days
Tailor Made
Avaiable
OEM/ODM
Avaiable
Capacity
1500-60000 Cfm
Refrigerant
Water
Motor
Low Noise
Coil
4rows/6rows/8rows
Panel Material
Double Skin with Polyurethane Fitting
Transport Package
Film/Wooden Package
Trademark
OEM/ODM/HYC
Origin
China
Production Capacity
50000sets

Product Description

Ventilation, Heating and Dehumidification Air Handling Unit--Air Conditioning SystemSincerely welcome to visit our factory at your convience. Customer could witness their order production real conditions by online videos or photos at any time during production.

WIDE AIR FLOW RANGE
Standardly, ceiling concealed type AHU air flow ranges from 1500 to 15000m3/h; horizontal/vertical type AHU air flow ranges from 2000 to 40000m3/h, able to fulfill various application requirements. Meanwhile, bigger air flow is available by tailor-made as customer special requirement. 

PANEL STRUCTURE DESIGN
Panel is made of powder coated double steel (outer and inner both) with high pressure polyurethane foam fitting in between, thus offering a rigid and robust panel. 
Frame is made of aluminum alloy which is fastened to the panel, as a result, the unit is strong and lightweight. 

LOW AIR LEAKAGE 
Thanks to the high pressure PU foam fitting, and special design insulation method to guarantee no low air leakage, to best minimize loss of energy. 

LOW NOISE 
Thanks to the rigidly bolted panel, dynamically and statically balanced fan assembly with spring isolator and closely integrated section, maximum to reduce the vibration and noise. 

COIL DESIGN
All coils are designed by professional computer selection software, proved through the lab testing and real life application. 
Model Coil Air flow Excess
pressure
Fresh air condition  Return air condition Noise Power
input
Weight
Cooling
capacity
Heating
capacity
Water
flow
Water
resistance
Cooling
capacity
Heating
capacity
Water
flow
Water
resistance
m³/h Pa kW kw L/S kPa kW kW L/S kPa dB(A) kW kg
2V/H 4ROWS 2000 236 27.1 33.2 1.3 13.4 11.2 22.9 0.5 6.7 56 0.55 101
6ROWS 196 33.5 50.3 1.6 18.9 14.9 27.9 0.7 9.5 0.55 104
3V/H 4ROWS 3000 298 40.5 54.9 2.0 32.6 17.3 35.2 0.8 16.3 57 0.8 128
6ROWS 258 47.7 77.1 2.5 38.7 22.8 42.0 1.1 19.4 0.8 134
4V/H 4ROWS 4000 253 54.7 79.5 2.6 41.1 23.2 47.3 1.1 20.6 59 1.1 146
6ROWS 213 63.6 103.3 3.3 55.9 29.6 55.5 1.5 28.0 1.1 150
5V/H 4ROWS 5000 286 68.4 102.3 3.3 49.5 28.2 57.2 1.4 24.8 60 1.5 176
6ROWS 246 79.9 118.6 3.8 61.2 34.4 64.5 1.8 30.6 1.5 182
6V/H 4ROWS 6000 263 81.6 124.7 4.0 56.3 35.5 69.3 1.7 28.2 61 1.5 216
6ROWS 223 97.4 147.5 4.7 65.3 42.7 78.8 2.2 32.7 1.5 227
7V/H 4ROWS 7000 296 89.9 141.7 4.5 42.8 41.0 81.1 2.0 21.4 62 1.8 240
6ROWS 256 115.9 174.7 5.6 50.5 50.2 92.8 2.6 25.3 1.8 251
8V/H 4ROWS 8000 262 101.7 152.6 4.9 51.8 48.2 93.7 2.3 25.9 63 2.2 259
6ROWS 222 124.7 205.8 6.6 59.1 58.5 106.5 3.1 29.6 2.2 271
10V/H 4ROWS 10000 358 145.4 203.6 6.9 60.3 58.0 115.5 3.0 30.2 65 3.7 304
6ROWS 318 162.8 265.3 8.5 68.5 74.5 138.0 3.6 34.3 3.7 328
12V/H 4ROWS 12000 296 157.1 247.7 7.9 66.2 69.8 136.8 3.7 33.1 66 4.5 358
6ROWS 256 193.8 319.8 10.2 72.2 89.0 165.3 4.3 36.1 4.5 376
15V/H 4ROWS 15000 490 194.1 315.3 10.0 72.5 90.6 172.7 4.3 36.3 67 6 429
6ROWS 450 252.4 409.9 13.1 84.2 115.7 207.4 5.6 42.1 6 528
20V/H 4ROWS 20000 358 270.3 358.5 13.4 28.8 125.9 247.0 6.0 14.4 65 3.7*2 550
6ROWS 318 331.1 463.8 15.8 37.8 157.4 289.2 7.5 18.9 3.7*2 682
25V/H 4ROWS 25000 443 320.7 454.9 15.5 31.6 148.8 285.5 7.1 15.8 66 5.5*2 638
6ROWS 403 381.6 629.6 20.1 41.5 182.4 332.2 9.0 20.8 5.5*2 753
30V/H 4ROWS 30000 490 384.0 575.9 18.3 40.8 187.6 357.5 9.0 20.4 68 6.0*2 753
6ROWS 450 472.6 779.8 24.8 52.2 227.3 413.4 11.7 26.1 6.0*2 841
35V/H 4ROWS 35000 529 454.2 698.3 22.2 45.6 221.1 416.5 10.4 22.8 70 8.0*2 841
6ROWS 489 550.7 908.7 28.9 57.0 274.2 486.5 13.2 28.5 8.0*2 1045
40V/H 4ROWS 40000 492 477.6 781.4 24.9 48.6 232.8 451.3 11.6 24.3 71 9*2 1012
6ROWS 452 615.2 1015.1 32.3 59.3 300.9 546.0 14.8 29.7 9*2 1265
50V/H 4ROWS 50000 443 605.0 798.6 29.4 53.4 285.0 538.0 15.0 26.7 73 11*2 1205
6ROWS 403 729.0 1105.5 35.2 64.1 390.0 685.5 20.5 32.1 11*2 1545
60V/H 4ROWS 60000 358 555.0 915.8 29.2 56.9 383.0 632.0 20.1 28.5 74 9*3 1492
6ROWS 318 701.0 1156.7 36.8 65.4 442.0 729.3 23.2 32.7 9*3 1790

Factory view
Ventilation, Heating and Dehumidification Air Handling Unit--Air Conditioning System

Production machinery
Ventilation, Heating and Dehumidification Air Handling Unit--Air Conditioning System
Test lab
Ventilation, Heating and Dehumidification Air Handling Unit--Air Conditioning System
AHU production line 
Ventilation, Heating and Dehumidification Air Handling Unit--Air Conditioning System

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours